Baldor DSM S Series Installation Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
www.baldormotion.com
5-4 Operation MN1940
5.2 Baldor SPI Interface
The Baldor SPI Interface is a simple application for configuring all aspects of the DSM.
5.2.1 Starting Baldor SPI Interface
On the Windows Start menu, select Programs, BALDOR SPI Interface, BALDOR SPI Interface.
The software will immediately try to establish communication with the DSM. If this step fails, the
word “Disconnected” will appear in red. Check that the DSM is powered and that the cable is
connected, then choose the Port menu item. Select the appropriate USB port from the list of
USB/Serial port options (this is the COM port number found in Windows Device Manager - see
section 5.1.4).
5.2.2 Configuration parameters
These parameters may all be changed ‘on-the-fly’. To select different views, choose the View
menu item.
5.2.2.1 M otion settings view
The motion settings view shows the main configuration parameters for the DSM:
Click in the boxes or use
the arrow buttons to
adjust values.
To send the changes to
the DSM, click Set.
To revert to default settings,
click Factory , followed by Set.
Parameter Name Range Units Default
MSEL Microstep resolution 1 - 256 microsteps
per step
256
MRC Motor run current 1 - 100 % 25
HCDT Motor hold current delay time 0 - 65000 ms 500
MHC Motor hold current 0 - 100 % 5
DIR Motor direction override CW or CCW CW
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 49 50

Comments to this Manuals

No comments