Input / Output 4-3MN1940
4.2.1 Wire sizes
Table 1 describes the wire sizes to provide optimal protection against EMI and RFI. Correct
wire size is determined by the current requirement and the cable length. The actual cable type,
wire gauge, shield type and filtering devices used are dependent on the customer’s application
and system. Always use shielded twisted pairs for AC and DC supply cables. For logic wiring
(see section 4.3) AWG22 wire is recommended.
Supply current
Cable length
(meters)
Cable length
(feet)
Minimum
Wire Gauge
(
)
(
)
AWG mm
2
3 10 20 0.5
8 25 20 0.5
1 A peak
15 50 18 1.0
p
23 75 18 1.0
30 100 16 1.3
3 10 20 0.5
8 25 18 1.0
2 A peak
15 50 16 1.3
p
23 75 14 2.0
30 100 14 2.0
3 10 18 1.0
8 25 16 1.3
3 A peak
15 50 14 2.0
p
23 75 12 3.3
30 100 12 3.3
3 10 18 1.0
8 25 16 1.3
4 A peak
15 50 14 2.0
p
23 75 12 3.3
30 100 12 3.3
Table1-Powerwireratings